Blog · Cameras & files

Radiometric Thermal Files: FLIR, HIKMICRO, Fluke, Testo and Raytron

What makes an image radiometric, what each camera brand saves, and how to tag photos to assets in the field.

An inspection report is only as good as the files behind it. If the camera saved a radiometric image, every pixel still holds a temperature you can measure next week. If it didn't, or something stripped it on the way, all you have is a coloured picture.

In short
  • Keep the camera's original files untouched; edit copies.
  • FLIR, HIKMICRO, Testo and Raytron/InfiRay files are read directly; Fluke .is2 needs a one-time temperature export.
  • Tag each photo with its asset number on the camera, so photos pair with the asset list automatically.
  • Save a visible photo with every thermal image.

Radiometric image vs. a picture of one

A radiometric image stores the measured value for every pixel along with the settings the camera used, such as emissivity, reflected temperature and distance. Software can measure any point, move spot and box markers, change the palette and recalculate with a corrected emissivity.

Thermal image of three overload heaters in a motor starter with a box reading 94.8 degrees Celsius
Every pixel is a temperature: the box finds the hottest point (94.8 °C) wherever it is drawn, long after the photo was taken. HIKMICRO radiometric JPEG, DTI Suite SuperRes picture.

A screenshot, a plain JPEG export or a photo re-saved in an image editor keeps none of that. The colours are there; the temperatures are not. Most lost data comes from three habits: editing originals, exporting "for the report" and emailing images through apps that recompress them. Copy the card, keep the originals, work on the copies.

What each camera brand saves

The five brands electrical thermographers use most each save something different, and each has its own way of attaching an asset number to a photo in the field:

Camera brandFileTemperaturesAsset tagging on the camera
FLIRRadiometric JPEG (.jpg)Read directlyText-annotation template (.tcf), loaded onto the camera by SD card (E-series, T-series)
HIKMICRORadiometric JPEG (.jpg)Read directlyNotes template (.json), loaded by SD card (G-series)
FlukeFluke image (.is2)Export all temperatures once in Fluke SmartView or Fluke Connect, saved beside the image with the same nameAnnotation list loaded through SmartView's Annotations Editor
TestoTesto image (.bmt)Read directlySiteRecognition: import a site/asset CSV in testo IRSoft and print the markers (872, 883, 890)
Raytron / InfiRayRadiometric image (.irg) and radiometric JPEGRead directlyNo annotation import: name the file by asset number, or tag the photo in DTI Suite

How DTI Suite handles each brand. Templates and the camera tagging guide (PDF) are on the download page.

Fluke .is2

Fluke keeps temperatures in a closed format. Open each image once in Fluke SmartView or Fluke Connect, use File ▸ Export to export all temperatures, and save the export beside the image with the same name. It is a one-time step per image; after that the photo can be measured like any other radiometric file.

Testo .bmt

Testo's own tagging is SiteRecognition: site markers rather than a text list. Import your asset list as a CSV in testo IRSoft, print the markers, and each photo identifies its asset when you shoot it.

Raytron / InfiRay .irg

These cameras have no annotation import. Rename each file to its asset number on the SD card, or tag it in the report software; either takes a few seconds per photo.

Tag photos to assets in the field

The asset number is what connects a photo to a row in the asset list. When it travels with the photo, from a camera annotation, a SiteRecognition marker or the file name, the photos pair to the spreadsheet automatically and nothing is retyped at the desk. Keep asset numbers the same from year to year and the same tag also lines up this year's photo with last year's, which is what makes trending possible.

Keep a visible photo with every thermal image

An electrician has to find the problem from the report. A thermal image of three identical breakers does not say which panel they are in. If your camera can save a separate visible photo with each thermal image, switch it on, and frame each shot so the equipment label is in view.

How DTI Suite uses these files

DTI Suite reads all five brands, pairs each photo to its asset in your Excel inventory, and lets you edit spot and box markers, read ΔT and switch palettes before the images go into a Word report. Import from Camera copies new photos from the camera or its SD card into the job folder without changing anything on the camera. The camera templates for FLIR, HIKMICRO, Fluke and Testo are free on the download page.

Questions

What is a radiometric thermal image?
An image that stores a temperature value for every pixel, plus the camera settings used. You can measure any point later, move markers and correct emissivity. A plain picture of a thermal image keeps only the colours.
Can I make a report from Fluke .is2 files?
Yes. Fluke keeps the temperatures in a closed format, so open each image once in Fluke SmartView or Fluke Connect, export all temperatures and save the export beside the image with the same name. DTI Suite then measures every pixel like a FLIR or HIKMICRO photo.
Do Testo .bmt and Raytron .irg files need converting?
No. DTI Suite reads Testo .bmt and Raytron/InfiRay .irg files directly.
Why did my thermal image lose its temperatures?
Usually because it was opened and re-saved in a photo editor, exported as a plain JPEG, or captured as a screenshot. Keep the original files from the camera untouched and work from copies.

Build the whole report in minutes

DTI Suite reads your radiometric photos, pairs them to your Excel asset list and writes the full Word report: summary, findings pages, severity matrix, re-inspection schedule and year-over-year trending. 30-day free trial, no credit card.

Start your free trial →